每天进步一点点分享 http://blog.sciencenet.cn/u/zjmjz 天行健,君子以自强不息;地势坤, 君子以厚德载物.

博文

逼近函数的构造(I)—插值

已有 4509 次阅读 2012-4-11 12:33 |个人分类:教学札记|系统分类:教学心得|关键词:学者| 记忆, 可靠性, 自变量, 多项式

逼近函数的构造(I)—插值

 

背景:所得采样数据信息具有较高的真实性和可靠性。
问题:被插值函数的复杂性和未知特点需构造简单函数(如代数多项式、三角多项式等)来近似表示未知函数。
条件:在节点处条件完全吻合。
方法:Lagrange插值,Newton插值,Hermite插值,样条插值,有理插值,连分式插值等。
分析:误差估计,插值的存在性,唯一性,适定性,不可达点(插值函数验证时不能满足插值条件的节点)分析等。

 

NOTE:
1 Lagrange插值结构对称、简单易于记忆,然而不具有承袭性。
2 Newton插值结构利用差商作为多项式的系数易于记忆且具有承袭性。
3 Hermite插值注意应用于带导数的插值,对插值函数的光滑性要求较高。
4 Spline插值(大部分会用 cubic spline),该方法是避免一味追求精度和提高次数可能会出现的Runge现象而提出。
5 当被插值函数在某节点处无界或当自变量趋于无穷时有固定的常数时,采用Rational插值和Continued fractional插值效果较好。特别是连分式插值具有递推公式,便于计算插值函数。
6 应用时根据需要灵活选择相应的插值方法。

7 应用案例 

Conventional computerised tomography systems (CT) are usually equipped with polyenergetic X-ray sources, which prevents accurate density measurements because of the general CT-image artefact called beam hardening (BH). BH results in false gradients of the linear attenuation coefficient in the CT cross section images, indicating a non-existent density or composition gradient in the imaged object. A number of methods have been proposed to correct for, or limit the effect of, beam hardening. One of these is called linearisation of the CT-data, in which the polyenergetic CT-data are transformed to monoenergetic CT-data. This requires knowledge of the CT-data as a function of object thickness. Data points to derive this function are usually measured using a set of samples of different object material thicknesses at the imaging parameter settings used and fitted with a polynomial. However, the sample preparation makes this method tedious to use. In this work a simulation method has been developed, which can accurately simulate the polyenergetic CT-data for any arbitrary object material and thickness if a priori information of the object material density and composition exists. The simulation method requires detailed knowledge of the imaging system, that is, X-ray energy spectra, detector response and information transfer from detector to digitised data. Besides developing the simulation tool, it has been shown that one of the major difficulties with this BH-correction method is to accurately determine the curvature of the function representing the polyenergetic CT-data. Earlier proposed endorsements to fit a second-degree polynomial to the polyenergetic CT-data are not sufficient to describe its curvature, at least a polynomial of degree eight or higher is required. Here cubic-spine interpolation is used, which avoids the problem.

(1998)"Correction for beam hardening artefacts in computerised tomography." J Xray Sci Technol 8(1): 75-93.



https://m.sciencenet.cn/blog-290784-558037.html

上一篇:第 I 型曲线积分
下一篇:第 II 型曲线积分

0

该博文允许注册用户评论 请点击登录 评论 (2 个评论)

数据加载中...

Archiver|手机版|科学网 ( 京ICP备07017567号-12 )

GMT+8, 2024-5-12 23:45

Powered by ScienceNet.cn

Copyright © 2007- 中国科学报社

返回顶部