这几天在 Power Globe 上看到对无功功率的一些讨论,把一些比较好的解释放到这里。正如Charles A. Gross 所说,这些解释都(部分地)正确地揭示或说明了无功功率,但也都不是一个完美或根本的解释,其中的一个原因是我们在尝试为一个非物理或抽象的量提供物理解释。 It’s been fun reading all the explanations. One of my favorites is “Q is the foam on the beer…”.They all have elements of truth, but never the whole truth and nothing but the truth. Hence, none really explain what Q is.The reason that we are having so much trouble coming up with a physical explanation for Q is that Q is non-physical, as are many concepts in engineering. --Charles A. Gross, PE, PhD, FIEEE Reactive power is a measure of the back and forth flow between energy in magnetic and electric fields in components. The reactive power value measures the magnitude of the instantaneous flow between these fields. ---B.Ross ------------------------------------------------------------------------------------------------------------- The answer to your question requires some understanding of ac circuits. Ac voltages (V) and currents(I) vary sinusoidally in time and have three basic properties: strength (RMS magnitude, V in volts, I in amperes); frequency (e.g. 60 Hz); and phase. Phase involves two quantities (V and I, in this case) . V and I are said to be “in phase”, if they both peak at the same instant; are zero at the same instant; reverse polarity/direction at same instant; etc. V and I are said to be “out of phase”, if when V peaks, I is zero, and vice versa. More precisely we really should say “V and I are 90 degrees out of phase”. . Now general, V and I are not in phase or 90 degrees out of phase but somewhere in between. It is possible to divide the current (I) into two components: the in-phase component or “active current” (IA) and the (90 deg) out-of-phase component or “reactive current” (IR) Correspondingly, there are two kinds of power: Active Power (P) = V*IA, which we say is measured in watts Reactive Power (Q) = V*IR, which we say is measured in volt-amperes reactive, or “vars” There is also a third kind of power in ac circuits: Apparent Power (S) = V*I, which we say is measured in volt-amperes , or “VA”. These three are related: S = sqrt as are the currents. I = sqrt How much of “I” is “IA” is communicated thru something called the power factor (pf), such that IA = I*pf and P = S*pf An Example: A 120 V ac source supplies 10 A at a pf = 0.8 lagging. The term lagging means that the current trails the voltage in time. Find S, P, and Q. S = V*I = 120(10) = 1200 VA P = S*pf = 1200(0.8) = 960 W Q= sqrt(1200^2-960^2)= 720 var I = 10 A IA = I*pf = 10(0.8) = 8 A IR = sqrt(10^2-80^2)= 6 A Now that we know what Q is, at least in terms of V, I, and phase, what is it physically? There are three passive circuit elements: R,L,C R, and only R, dissipates active power (P). L and C are called “reactive elements” in that they do not dissipate energy, but they do store it an internal magnetic field (L), or electric field (C). This field energy” is constantly flowing into and out of L and C and the source, and over an ac cycle, averages to zero. This energy exchange requires a current component that is necessarily 90 deg out of phase with the voltage (IR), and hence a corresponding power component Q = V*IR. --- Charles A. Gross, PE, PhD, FIEEE ---------------------------------------------------------------------------------------------------------------------------------------------------- Reactive power is a myth and a delusion. It is no more than a mathematical coincidence. It can be extremely useful, but it is without foundation. You know the math: it is just a matter of using a sine or a cosine term to switch between real and reactive power. It is just the difference between the one side or the other of a right-angle triangle. But think! That right triangle does not represent a phasor. The 90-degree rotation business of phasors does not apply because power is not a phasor. A few years ago, NIST did a survey of the way this thing called reactive power was being measured, and found there were at least nine different methods that would give nine different results, depending on how far the waveform was from sinusoidal. It became a NEMA report: NEMA C12.24 TR-2011, Definitions for Calculations of VA, VAh, VAR, and VARh for Poly-Phase Electricity Meters, registered with ANSI May 2011. Over a hundred years ago, we engineers were asking whether it was possible to measure something that was not real, and whether the fact that you could measure something meant that it was real. The digital revolution in measurements has firmly answered that it is possible to measure something that is not real, because the number-crunching part of measurement is no more than data compression. The ways we measure reactive power underlines that. Today, you can buy equipment that will let you choose whose definition you use in the measurement. That is not to say the idea of reactive power is not useful. It has simplified thinking about voltage management in the power system. It has led to some interesting solutions in that area: SVCs for example. But once you get away from the simplified notion of a perfect sine-wave, you enter undefined territory, the realm of imagination. Power factor is in the same boat. Another calculation of very great value and usefulness, and yet not defined for waves that are not sinusoidal. We will, of course, continue to use these terms: they are much too useful to abandon. But we should be aware of their limited meaning, and sometimes we are not. See, for example, Berrisford, A.J., “Smart Meters should be smarter”, presented at the IEEE PES General Meeting, San Diego, CA July 2012. DOI 10.1109/PESGM.2012.6345146 --- Harold Kirkham,Staff Scientist,Pacific Northwest National Laboratory.
我们从 Wiley 出版的电气工程、控制系统、电路理论和通信技术类期刊中,选取了过去三个月 内下载量最高的 25 篇文章,推荐给大家免费阅读,时间有限,大家抓住机会。 Analysis of possible introduction of PV systems considering output power fluctuations and battery technology, employing an optimal power generation mix model Electrical Engineering in Japan Semi-Global Output Feedback Stabilization for a Class of Uncertain Nonlinear Systems Asian Journal of Control A signal processing adaptive algorithm for nonstationary power signal parameter estimation International Journal of Adaptive Control and Signal Processing A novel design of compact wideband hexagonal antenna Microwave and Optical Technology Letters Distributed Tracking Control for Networked Mechanical Systems Asian Journal of Control Robust stability of nonlinear model predictive control with extended Kalman filter and target setting International Journal of Robust and Nonlinear Control Globally decentralized adaptive backstepping neural network tracking control for unknown nonlinear interconnected systems. Asian Journal of Control Planar UWB monopole antenna with dual band-notched characteristics for UWB applications Microwave and Optical Technology Letters Multiobjective particle swarm optimization for a novel fuzzy portfolio selection problem IEEJ Transactions on Electrical and Electronic Engineering Low-power, low-area preamplifier for ultra high-speed multi-channel optical communication system International Journal of Circuit Theory and Applications Composite adaptive disturbance observer?based control for a class of nonlinear systems with multisource disturbance International Journal of Adaptive Control and Signal Processing Consensus of multi-agent systems with nonlinear dynamics and sampled-data information: a delayed-input approach International Journal of Robust and Nonlinear Control A model-driven development method for Management Information Systems Electronics and Communications in Japan Microlens for uncooled infrared array sensor Electronics and Communications in Japan Distributed output regulation of leader–follower multi-agent systems International Journal of Robust and Nonlinear Control Bounded Consensus Algorithms for Multi-Agent Systems in Directed Networks Asian Journal of Control RC models of a constant phase element International Journal of Circuit Theory and Applications Robust control of robot manipulators based on uncertainty and disturbance estimation International Journal of Robust and Nonlinear Control A 5-GHz energy-efficient tunable pulse generator for ultra-wideband applications using a variable attenuator for pulse shaping International Journal of Circuit Theory and Applications Inactivation property of microorganisms in water irradiated by atmospheric-pressure plasma using dielectric barrier discharge IEEJ Transactions on Electrical and Electronic Engineering Nonlinear convex and concave relaxations for the solutions of parametric ODEs Optimal Control Applications and Methods A CCII-based wide frequency range square waveform generator International Journal of Circuit Theory and Applications Hybrid modelling and emulation of mem-systems International Journal of Numerical Modelling: Electronic Networks, Devices and Fields 1 x 8 MEMS Flexible integrated optical device for optical fiber-based networking applications Microwave and Optical Technology Letters Decoupled WWAN/LTE antennas with an isolation ring strip embedded therebetween for smartphone application Microwave and Optical Technology Letters