Acoustic Transducer
The effective coupling coefficient is 3.08 %. The quality factor Q value is 39.96.
Schematic diagram of the test setup for evaluating the acoustic transmission performance of the devices. The setup was in an anechoic chamber. A B&K 4196 microphone with known sensitivity as reference.
Both the sensitivity and the sound pressure level (SPL= 20log(sound pressure /20 μPa)), peaks appear at the resonance of 13.71 kHz. The 1 kHz sensitivity of the d33 mode diaphragm (126.21 μV/Pa), is nearly 20 times of the sensitivity (6.5 μV/Pa) of a d31 mode thick film diaphragm with the same material and similar dimensions.
A 3 × 3 array was fabricated. Each element can be controlled independently. Directivity pattern of the array was tested. The array has the potential to be used as a phase array.